In 2002, workers at the Swedish National Food Administration discovered that heated, carbohydrate-rich foods, such as french

Question:

In 2002, workers at the Swedish National Food Administration discovered that heated, carbohydrate-rich foods, such as french fries, potato chips, and bread, contain alarming levels (0.1 to 4 μg/g) of acrylamide, a known carcinogen.32
In 2002, workers at the Swedish National Food Administration discovered

After the discovery, simplified methods were developed to measure ppm levels of acrylamide in food. In one procedure, 10 g of pulverized, frozen french fries were mixed for 20 min with 50 mL of H2O to extract acrylamide, which is very soluble in water (216 g/100 mL). The liquid was decanted and centrifuged to remove suspended

In 2002, workers at the Swedish National Food Administration discovered

matter. The internal standard 2H3-acrylamide was added to 1 mL of extract. A solid-phase extraction column containing 100 mg of cation-exchange polymer with protonated sulfonic acid groups (OSO3H) was washed twice with 1-mL portions of methanol and twice with 1-mL portions of water. The aqueous food extract (1 mL) was then passed through the column to bind protonated acrylamide (O) to sulfonate (O) on the column. The column was dried for 30 s at 0.3 bar and then acrylamide was eluted with 1 mL of H2O. Eluate was analyzed by liquid chromatography with a polar bonded phase. The chromatograms show the results monitored by ultraviolet absorbance or by mass spectrometry. The retention time of acrylamide is different on the two columns because they have different dimensions and different flow rates.
(a) What is the purpose of solid-phase extraction prior to chromatography? How does the ion-exchange sorbent retain acrylamide?
(b) Why are there many peaks when chromatography is monitored by ultraviolet absorbance?
(c) Mass spectral detection used selected reaction monitoring (Figure 21-26) with the m/z transition for acrylamide and for 2H3-acrylamide. Explain how this detection method works and suggest structures for the ions with m/z 72 and 55 from acrylamide.
(d) Why does mass spectral detection give just one major peak?
(e) How is the internal standard used for quantitation with mass spectral detection?
(f) Where does 2H3-acrylamide appear with ultraviolet absorbance? With mass spectral selected reaction monitoring?
(g) Why does the mass spectral method give quantitative results even though retention of acrylamide by the ion-exchange sorbent is not quantitative and elution of acrylamide from the sorbent by 1 mL of water might not be quantitative?

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question
Question Posted: