Optimize the design of Example 12.3 using commercial heat exchanger design software. Data from example 12.3 Design

Question:

Optimize the design of Example 12.3 using commercial heat exchanger design software.

Data from example 12.3

Design a shell-and-tube exchanger for the following duty. 20,000kg/h of kerosene (42° API) leaves the base of a kerosene side-stripping column at 200°C and is to be cooled to 90°C by exchange with 70,000 kg/h light crude oil (34°API) coming from storage at 40°C. The kerosene enters the exchanger at a pressure of 5 bar and the crude oil at 6.5 bar. A pressure drop of 0.8 bar is permissible on both streams. Allowance should be made for fouling by including a fouling factor of 0.0003 (W/m°C) –1 on the crude stream and 0.0002 (W/m°C) –1 on the kerosene stream.