The design for a new cementless hip implant is to be studied using an instrumented implant and

Question:

The design for a new cementless hip implant is to be studied using an instrumented implant and a fixed simulated femur. Assuming the punch applies an average force of 2 kN over a time of 2 ms to the 200 g implant.

The design for a new cementless hip implant is to

Determine
(a) The velocity of the implant immediately after impact,
(b) The average resistance of the implant to penetration if the implant moves 1 mm before coming to rest.