A 25-kW, 230-V shunt motor has an armature resistance of 0.11 and a field resistance of 117.

Question:

A 25-kW, 230-V shunt motor has an armature resistance of 0.11Ω and a field resistance of 117Ω. At no load and rated voltage, the speed is 2150 r/min and the armature current is 6.35 A. At full load and rated voltage, the armature current is 115 A and, because of armature reaction, the flux is 6 percent less than its no-load value. What is the full-load speed?

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Electric Machinery

ISBN: 978-0071230100

6th Edition

Authors: Charles Kingsley, Jr, Stephen D. Umans

Question Posted: