The schematic of a single-flash geothermal power plant with state numbers is given in Fig. P18-91. Geothermal

Question:

The schematic of a single-flash geothermal power plant with state numbers is given in Fig. P18-91. Geothermal resource exists as saturated liquid at 230oC. The geothermal liquid is withdrawn from the production well at a rate of 230 kg/s, and is flashed to a pressure of 500 kPa by an essentially isenthalpic flashing process where the resulting vapor is separated from the liquid in a separator and directed to the turbine. The steam leaves the turbine at 10 kPa with a moisture content of 10 percent and enters the condenser where it is condensed and routed to a reinjection well along with the liquid coming off the separator. Determine (a) The mass flow rate of steam through the turbine
(b) The isentropic efficiency of the turbine
(c) The power output of the turbine
(d) The thermal efficiency of the plant (the ratio of the turbine work output to the energy of the geothermal fluid relative to standard ambient conditions).
The schematic of a single-flash geothermal power plant with state
Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Thermodynamics An Engineering Approach

ISBN: 978-0073398174

8th edition

Authors: Yunus A. Cengel, Michael A. Boles

Question Posted: