Air enters a length of constant area pipe with (p_{1}=200) (mathrm{kPa}(mathrm{abs}), T_{1}=500 mathrm{~K}), and (V_{1}=400 mathrm{~m} /

Question:

Air enters a length of constant area pipe with \(p_{1}=200\) \(\mathrm{kPa}(\mathrm{abs}), T_{1}=500 \mathrm{~K}\), and \(V_{1}=400 \mathrm{~m} / \mathrm{s}\). If \(500 \mathrm{~kJ} / \mathrm{kg}\) of energy is removed from the air by frictionless heat transfer between sections (1) and (2), determine \(p_{2}, T_{2}\), and \(V_{2}\). Sketch a temperature-entropy diagram for the flow between sections (1) and (2).

Step by Step Answer:

Related Book For  book-img-for-question

Munson Young And Okiishi's Fundamentals Of Fluid Mechanics

ISBN: 9781119080701

8th Edition

Authors: Philip M. Gerhart, Andrew L. Gerhart, John I. Hochstein