A specimen of dense sand tested in a triaxial CD test failed along a well-defined failure plane

Question:

A specimen of dense sand tested in a triaxial CD test failed along a well-defined failure plane at an angle of 62° with the horizontal. Find the effective confining pressure of the test if the principal stress difference at failure was 115 kPa.

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

An Introduction to Geotechnical Engineering

ISBN: 978-0132496346

2nd edition

Authors: Robert D. Holtz, William D. Kovacs, Thomas C. Sheahan

Question Posted: