Question: A binary mixture of benzene(1) and toluene(2) is flashed to 75 kPa and 90C. Analysis of the effluent liquid and vapor streams from the separator
A binary mixture of benzene(1) and toluene(2) is flashed to 75 kPa and 90°C. Analysis of the effluent liquid and vapor streams from the separator yields: x1 = 0.1604 and y1 = 0,2919.
An operator remarks that the product streams arc "'off-spec," and you are asked to diagnose the problem.
(a) Verify that the exiting streams are not in binary equilibrium.
(b) Verify that an air Leak into (he separator could be the cause.
Step by Step Solution
3.40 Rating (175 Votes )
There are 3 Steps involved in it
Calculate x and y at T 90 C and P 75 kPa Benzene Toluene a Calculate the ... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
946-E-C-E-S-P (982).docx
120 KBs Word File