A lake with a constant volume of 10 x 106 m3 is fed by a pollution-free stream

Question:

A lake with a constant volume of 10 x 106 m3 is fed by a pollution-free stream with flow rate 50 m3/s. A factory discharges 5 m3/s of a non-conservative waste with concentration 100 mg/L into the lake. The pollution has a reaction rate coefficient K of 0.25/day.
Assuming the pollution is well mixed in the lake, find the steady-state concentration of the pollution in the lake.
A lagoon with a volume of 1200m3
Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Elementary Principles of Chemical Processes

ISBN: 978-1119498759

4th edition

Authors: Richard M. Felder, ‎ Ronald W. Rousseau, ‎ Lisa G. Bullard

Question Posted: