A twin-tube, counter flow heat exchanger operates with balanced flow rates of 0.003 kg/s for the hot and cold airstreams. The cold stream enters at 280 K and must be heated to 340 K using hot air at 360 K. The average pressure of the airstreams is 1 atm and the maximum allowable pressure drop for the cold air is 10 kPa. The tube walls may be assumed to act as fins, each with an efficiency of 100%.
(a) Determine the tube diameter D and length L that satisfy the prescribed heat transfer and pressure drop requirements.
(b) For the diameter D and length L found in part (a) generate plots of the cold stream outlet temperature, the heat transfer rate, and pressure drop as a function of balanced flow rates in the range from 0.002 to 0.004 kg/s. Comment on your results.

Hot air Copper tubes Cold air
Step by Step Solution
3.24 Rating (153 Votes )
There are 3 Steps involved in it
KNOWN Twintube counterflow heat exchanger with balanced flow rates m 0003 kgs Cold airstream enters at 280 K and must be heated to 340 K Maximum allowable pressure drop of cold airstream is 10 kPa FIN... View full answer