Question: A certain industrial process requires a steady 0.5 kg/s supply of compressed air at 500 kPa, at a maximum temperature of 30C. This air is

A certain industrial process requires a steady 0.5 kg/s supply of compressed air at 500 kPa, at a maximum temperature of 30C. This air is to be supplied by installing a compressor and after cooler. Local ambient conditions are 100 kPa, 20C. Using an isentropic compressor efficiency of 80%, determine the power required to drive the compressor and the rate of heat rejection in the after cooler.

Step by Step Solution

3.30 Rating (156 Votes )

There are 3 Steps involved in it

1 Expert Approved Answer
Step: 1 Unlock

Air R 0287 kJkgK Cp 1004 kJkgK k 14 State 1 T To 20C P Po 100 kPa m 05 kgs State 2 P2 P3 500 ... View full answer