A condenser (heat exchanger) brings 1 kg/s water flow at 10 kPa from 300C to saturated liquid

Question:

A condenser (heat exchanger) brings 1 kg/s water flow at 10 kPa from 300C to saturated liquid at 10 kPa. The cooling is done by lake water at 20C that returns to the lake at 30C. For an insulated condenser, find the flow rate of cooling water.
Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Fundamentals Of Thermodynamics

ISBN: 9781118131992

8th Edition

Authors: Claus Borgnakke, Richard E. Sonntag

Question Posted: