Question: Data by A. T. Lenz for water at 20°C (reported in Ref. 19) show a significant increase of discharge coefficient of V-notch weirs (Fig. P10.118)

Data by A. T. Lenz for water at 20°C (reported in Ref. 19) show a significant increase of discharge coefficient of V-notch weirs (Fig. P10.118) at low heads, for α = 20°, some measured values are as follows:

Data by A. T. Lenz for water at 20°C

H, ft Cd: 0.2 0.4 0.6 0.8 1. 0.499 0.470 0461 0.456 0.452

Step by Step Solution

3.48 Rating (158 Votes )

There are 3 Steps involved in it

1 Expert Approved Answer
Step: 1 Unlock

There is little or no Reynolds number effect We can ascribe the entire effect ... View full answer