Question: A freezer compartment is covered with a 2-mm-thick layer of frost at the time it malfunctions. If the compartment is in ambient air at 20C
A freezer compartment is covered with a 2-mm-thick layer of frost at the time it malfunctions. If the compartment is in ambient air at 20°C and a coefficient of h = 2 W/m2 ∙ K characterizes heat transfer by natural convection from the exposed surface of the layer, estimate the time required to completely melt the frost. The frost may be assumed to have a mass density of 700 kg/m3 and a latent heat of fusion of 334kJ/kg.
Step by Step Solution
3.36 Rating (159 Votes )
There are 3 Steps involved in it
KNOWN Frost formation of 2mm thickness on a freezer compartment Surface exposed to convection proces... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
8-P-T-H-M-T (50).docx