Question: Heated air required for a food-drying process is generated by passing ambient air at 20C through long, circular tubes (D = 50 mm, L =
Heated air required for a food-drying process is generated by passing ambient air at 20°C through long, circular tubes (D = 50 mm, L = 5 m) housed in a steam condenser. Saturated steam at atmospheric pressure condenses on the outer surface of the tubes, maintaining a uniform surface temperature of 100°C.
(a) If an air flow rate of 0.0 I kg/s is maintained in each tube, determine the air outlet temperature Tm,o and the total heat rate q for the tube.
(b) The air outlet temperature may be controlled by adjusting the tube mass flow rate. Compute and plot Tm,o as a function of m for 0.005
Step by Step Solution
3.51 Rating (164 Votes )
There are 3 Steps involved in it
KNOWN Diameter length and surface temperature of tubes used to heat ambient air Flowrate and inlet temperature of air FIND a Air outlet temperature an... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
8-E-M-E-H-M-T (745).docx