Question: A power plant with one open feedwater heater has a condenser temperature of 45C, a maximum pressure of 5 MPa, and boiler exit temperature of
A power plant with one open feedwater heater has a condenser temperature of 45°C, a maximum pressure of 5 MPa, and boiler exit temperature of 900°C. Extraction steam at 1 MPa to the feedwater heater is mixed with the feedwater line so the exit is saturated liquid into the second pump. Find the fraction of extraction steam flow and the two specific pump work inputs.
Step by Step Solution
3.44 Rating (157 Votes )
There are 3 Steps involved in it
State out of boiler 5 h5 437882 5 79593 CV Turbine 7 6 5 P6 S6 h636406 T6 574C ... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
E-ME-T (3481).docx