Question: Refrigerant-134a at 1 MPa and 90°C is to be cooled to 1 MPa and 30°C in a condenser by air. The air enters at 100

Refrigerant-134a at 1 MPa and 90°C is to be cooled to 1 MPa and 30°C in a condenser by air. The air enters at 100 kPa and 27°C with a volume flow rate of 600 m3/min and leaves at 95 kPa and 60°C. Determine the mass flow rate of the refrigerant.

Refrigerant-134a at 1 MPa and 90°C

AIR V-600 m /min Pg = 100 kPa T3 = 27C T, = 90C 95 kPa ,-60C P p,01 7-30C MPa

Step by Step Solution

3.41 Rating (167 Votes )

There are 3 Steps involved in it

1 Expert Approved Answer
Step: 1 Unlock

Refrigerant134a is to be cooled by air in the condenser For a specified volume flow rate of air the ... View full answer