Question: A small steam power plant has a boiler exit of 3 MPa, 400C while it maintains 50 kPa in the condenser. All the components are
A small steam power plant has a boiler exit of 3 MPa, 400°C while it maintains 50 kPa in the condenser. All the components are ideal except the turbine which has an isentropic efficiency of 80% and it should deliver a shaft power of 9.0 MW to an electric generator. Find the specific turbine work , the needed flow rate of steam and the cycle efficiency.
Step by Step Solution
3.44 Rating (173 Votes )
There are 3 Steps involved in it
CV Turbine Ideal 45 3 1145 109165029 08965 240735 h 32308 WTS1314s 823... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
E-ME-T (3496).docx