5400 m 3 /h of wet steam 0.92 dry and at 10 bar is to be supplied...

Question:

5400 m3/h of wet steam 0.92 dry and at 10 bar is to be supplied by a boiler for a processing plant. Calculate

(a) the mass of steam supplied per hour, and

(b) the quantity of coal of calorific value 15 MJ to be burnt in boiler if over all efficiency of boiler is 30\%.