Question: You are using proportional control (G c =K c ) for a process with G v = 4 / 2s + 1 and G p
You are using proportional control (Gc =Kc) for a process with Gv = 4 / 2s + 1 and Gp 0.6 / 50s + 1 (time constants in s). You have a choice of two measurements, both of which exhibit first order dynamic behavior. Gm1 = 2 / s + 1 and Gm2 = 2 / 0.4s + 1. Can Gc be made unstable for either process?
Which measurement is preferred for the best stability and performance properties? Why?
Step by Step Solution
3.42 Rating (161 Votes )
There are 3 Steps involved in it
Characteristic equation s 1 50s 12s 1 K c 4 2 06 0 1 For a th... View full answer