Question: The primary windings of a transformer which has 88% efficiency are connected to 110-V ac. The secondary windings are connected across a 2.4-, 75-W light
The primary windings of a transformer which has 88% efficiency are connected to 110-V ac. The secondary windings are connected across a 2.4-Ω, 75-W light bulb.
(a) Calculate the current through the primary windings of the transformer.
(b) Calculate the ratio of the number of primary windings of the transformer to the number of secondary windings of the transformer.
Step by Step Solution
3.40 Rating (150 Votes )
There are 3 Steps involved in it
a From the efficiency of the transformer we have Use this to calculate ... View full answer