Question: The pump of Prob. 11.28 is scaled up to an 18-in-diameter, operating in water at BEP at 1760 rpm. The measured NPSH is 16 ft,
The pump of Prob. 11.28 is scaled up to an 18-in-diameter, operating in water at BEP at 1760 rpm. The measured NPSH is 16 ft, and the friction loss between the inlet and the pump is 22 ft. Will it be sufficient to avoid cavitation if the pump inlet is placed 9 ft below the surface of a sea-level reservoir?
Step by Step Solution
3.45 Rating (158 Votes )
There are 3 Steps involved in it
For water at 20C take g 624 lbfft3 and pv 49 psfa Since th... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
E-ME-FM (1348).docx