Question: A water-heater is covered up with insulation boards over a total surface area of 3 m2. The inside board surface is at 75C and the

A water-heater is covered up with insulation boards over a total surface area of 3 m2. The inside board surface is at 75°C and the outside surface is at 20°C and the board material has a conductivity of 0.08 W/m K. How thick a board should it be to limit the heat transfer loss to 200 W?

Step by Step Solution

3.39 Rating (149 Votes )

There are 3 Steps involved in it

1 Expert Approved Answer
Step: 1 Unlock

Steady state conduct... View full answer