A 460-V: 2400-V transformer has a series leakage reactance of 37.2 as referred to the high-voltage side.

Question:

A 460-V: 2400-V transformer has a series leakage reactance of 37.2Ω as referred to the high-voltage side. A load connected to the low-voltage side is observed to be absorbing 25 kW, unity power factor, and the voltage is measured to be 450 V. Calculate the corresponding voltage and power factor as measured at the high-voltage terminals.