Question: A 1.0-mm-diameter wire is maintained at a temperature of 400C and exposed to a convection environment at 40C with h = 120 W/m2 C.
A 1.0-mm-diameter wire is maintained at a temperature of 400ºC and exposed to a convection environment at 40ºC with h = 120 W/m2 ∙ ºC. Calculate the thermal conductivity that will just cause an insulation thickness of 0.2 mm to produce a "critical radius." How much of this insulation must be added to reduce the heat transfer by 75 percent from that which would be experienced by the bare wire?
Step by Step Solution
3.28 Rating (154 Votes )
There are 3 Steps involved in it
r i 05 mm 5 x 10 4 m qbare wire ... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
892-P-T-H-T (675).docx