Question: A refrigerator in a meat warehouse must keep a low temperature of -15C and the outside temperature is 20C. It uses R-12 as the refrigerant

A refrigerator in a meat warehouse must keep a low temperature of -15°C and the outside temperature is 20°C. It uses R-12 as the refrigerant which must remove 5 kW from the cold space. Find the flow rate of the R-12 needed assuming a standard vapor compression refrigeration cycle with a condenser at 20°C.

Step by Step Solution

3.39 Rating (165 Votes )

There are 3 Steps involved in it

1 Expert Approved Answer
Step: 1 Unlock

Basic refrigeration cycle T 1 T 4 15... View full answer