An RC filter stage (R = 33 (, C = 120 (F) is used to filter a

Question:

An RC filter stage (R = 33 (, C = 120 (F) is used to filter a signal of 24 V dc with 2 V rms operating from a full-wave rectifier. Calculate the percentage ripple at the output of the RC section for a 100-mA load. Also calculate the ripple of the filtered signal applied to the RC stage.