Question: Consider a steam power plant that operates on a regenerative Rankine cycle and has a net power output of 150 MW. Steam enters the turbine
Consider a steam power plant that operates on a regenerative Rankine cycle and has a net power output of 150 MW. Steam enters the turbine at 10 MPa and 500°C and the condenser at 10 kPa. The isentropic efficiency of the turbine is 80 percent, and that of the pumps is 95 percent. Steam is extracted from the turbine at 0.5 MPa to heat the feedwater in an open feedwater heater. Water leaves the feedwater heater as a saturated liquid. Show the cycle on a T-s diagram, and determine
(a) The mass flow rate of steam through the boiler, and
(b) The thermal efficiency of the cycle. Also, determine the exergy destruction associated with the regeneration process. Assume a source temperature of 1300 K and a sink temperature of 303 K.
.png)
Turbine Boiler Open FWH Condenser Pump II PumpI FIGURE P10-94
Step by Step Solution
3.48 Rating (174 Votes )
There are 3 Steps involved in it
An 150MW steam power plant operating on a regenerative Rankine cycle with an open feedw... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
837-ME-T (5841).docx