Question: Consider an underground limestone mine in flat strata where pillars are 29 m high and depth is 258 m. Rock properties are: E = 77.9GPa,

Consider an underground limestone mine in flat strata where pillars are 29 m high and depth is 258 m. Rock properties are: E = 77.9GPa, v = 0.20, Co = 148 MPa, To = 11.6 MPa, unit weight = 24.7kN/m3. A joint set of variable dip pervades the mine. Mohr–Coulomb properties are: c = 4.34 MPa, φ = 40◦. Pillars must have a safety factor of 2.5 with respect to any potential failure mechanism. Is this possible? Show why or why not.

Step by Step Solution

3.36 Rating (168 Votes )

There are 3 Steps involved in it

1 Expert Approved Answer
Step: 1 Unlock

Given Room of pillar limestone mine Hp 29m h258 m depth Rock E 779 GPa v020 ... View full answer

blur-text-image
Question Has Been Solved by an Expert!

Get step-by-step solutions from verified subject matter experts

Step: 2 Unlock
Step: 3 Unlock

Document Format (1 attachment)

Word file Icon

26-E-G-R (285).docx

120 KBs Word File

Students Have Also Explored These Related Geological Engineering Questions!