Question: Evaluate the performance and robustness of alternative decoupling control systems. In particular, robustness to errors in the assumed process model will be of interest. Use
Evaluate the performance and robustness of alternative decoupling control systems. In particular, robustness to errors in the assumed process model will be of interest. Use MATLAB to simulate the Wood-Berry distillation column model in Example 18.1. Perform a computer simulation of the controlled process to answer the following questions:(a) For the ideal case of a perfect process model, which of the following three controllers provides the best set-point responses: dynamic decoupler, static decoupler, or conventional multiloop PI control? Use these PI controller settings for all three cases:(b) Does the dynamic decoupling control scheme exhibit a reasonable degree of robustness to modeling errors? In order to answer this question, evaluate decoupling controller parameters that correspond to one or more of the assumed process gains being incorrect (+20% error), Repeat for the assumed process time constants using +20% K11, + 20% K11+20% K11 and + 20% K22, +20% ?11, and + 20% ?22.
:
Ke - 0.85, T1 - 7.21 min for the o-R loop; Ke = -0.089, 71 - 8.86 min for the xa-S loop.
Step by Step Solution
3.45 Rating (171 Votes )
There are 3 Steps involved in it
Multiloop PI control system reported by Lee et al a PERFECT PROCESS MODEL By using SimulinkMATLAB un... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
38-E-C-E-P-C (305).docx
120 KBs Word File