Question: In a dairy plant, milk at 4C is pasteurized continuously at 72C at a rate of 12 L/s for 24 h/day and 365 days/yr. The
In a dairy plant, milk at 4°C is pasteurized continuously at 72°C at a rate of 12 L/s for 24 h/day and 365 days/yr. The milk is heated to the pasteurizing temperature by hot water heated in a natural gas-fired boiler having an efficiency of 82 percent. The pasteurized milk is then cooled by cold water at 18°C before it is finally refrigerated back to 4°C. To save energy and money, the plant installs a regenerator that has an effectiveness of 82 percent. If the cost of natural gas is $1.04/therm (1 therm = 105,500 kJ), determine how much energy and money the regenerator will save this company per year and the annual reduction in energy destruction.
Step by Step Solution
3.18 Rating (165 Votes )
There are 3 Steps involved in it
A regenerator is considered to save heat during the cooling of milk in a dairy plant The amounts of fuel and money such a generator will save per year ... View full answer