A refrigerator uses a power input of 2.5 kW to cool a 5C space with the high temperature in the cycle as 50C. The QH
Answered step by step
Verified Expert Solution
Question
A refrigerator uses a power input of 2.5 kW to cool a 5°C space with the high temperature in the cycle as 50°C. The QH is pushed to the ambient air at 35°C in a heat exchanger where the transfer coefficient is 50 W/m2K. Find the required minimum heat transfer area.
66 users unlocked this solution today!
Step by Step Solution
★★★★★
3.38 Rating (148 Votes )
There are 3 Steps involved in it
1 Expert Approved Answer
Step: 1
W25 kWQHBHP QH W ... View full answer