Question: Repeat Prob. 10-45 by replacing the open feedwater heater with a closed feedwater heater. Assume that thefeedwater leaves the heater at the condensation temperature of

Repeat Prob. 10-45 by replacing the open feedwater heater with a closed feedwater heater. Assume that thefeedwater leaves the heater at the condensation temperature of the extracted steam and that the extracted steam leaves the heater as a saturated liquid and is pumped to the line carrying the feedwater.
Prob. 10-45
A steam power plant operates on an ideal regenerative Rankine cycle. Steam enters the turbine at 6 MPa and 450°C and is condensed in the condenser at 20 kPa. Steam is extracted from the turbine at 0.4 MPa to heat the feedwater in an open feedwater heater. Water leaves the feedwater heater as a saturated liquid. Show the cycle on a T-s diagram, and determine (a) the net work output per kilogram of steam flowing through the boiler and
(b) the thermal efficiency of the cycle