A starter is connected to a motor that is connected to a pump. The starter fails once
Question:
A starter is connected to a motor that is connected to a pump. The starter fails once in 50 years and requires 2 hours to repair. The motor fails once in 20 years and requires 36 hours to repair. The pump fails once per 10 years and requires 4 hours to repair. Determine the overall failure frequency, the probability that the system will fail in the coming 2 years, the reliability, and the unavailability for this system.