A mechanical support framing system is shown in Figure P2.11. The framing consists of steel floor grating

Question:

A mechanical support framing system is shown in Figure P2.11. The framing consists of steel floor grating over steel beams and entirely supported by four tension hangers that are connected to floor framing above it. It supports light machinery with an operating weight of \(4000 \mathrm{lbs}\), centrally located.

(a) Determine the impact factor \(I\) from the Live Load Impact Factor, Table 2.3.

(b) Calculate the total live load acting on one hanger due to the machinery and uniform live load of \(40 \mathrm{psf}\) around the machine.

(c) Calculate the total dead load acting on one hanger. The floor framing dead load is \(25 \mathrm{psf}\). Ignore the weight of the hangers. Lateral bracing is located on all four edges of the mechanical floor framing for stability and transfer of lateral loads.

hanger 2.57 5' 2.57 hanger hanger- 3' 10' mechanical unit Mechanical Floor Plan (beams not shown) mechanical

Table 2.3

TABLE 2.3 Live Load Impact Factor Loading Case Supports of elevators and elevator machinery Supports of light

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  answer-question

Fundamentals Of Structural Analysis

ISBN: 9780073398006

5th Edition

Authors: Kenneth Leet, Chia-Ming Uang, Joel Lanning

Question Posted: