Question: Solve Example 5.3 with the addition of a heat exchanger at each stage so as to maintain isothermal operation of the absorber at: (a) 125
Solve Example 5.3 with the addition of a heat exchanger at each stage so as to maintain isothermal operation of the absorber at:

(a) 125οF and
(b) 150οF.
What is the effect of temperature on absorption in this range?
EXAMPLE 5.3 Absorption of Hydrocarbons by Oil. In Figure 5.11, the heavier components in a superheated hydro- carbon gas are to be removed by absorption at 400 psia with a high- molecular-weight oil. Estimate exit vapor and liquid flow rates and compositions by the Kremser method, using estimated component absorption and stripping factors from the entering values of L and V, and the component K-values below based on an average entering temperature of (90+105)/2 = 97.5F.
Step by Step Solution
3.32 Rating (158 Votes )
There are 3 Steps involved in it
a For a temperature of 125F the Kremser method can be used to calculate the exit vapor and liquid fl... View full answer
Get step-by-step solutions from verified subject matter experts