Question: The primary objective of many control systems is to maintain the output variable at the desired or reference condition when the system is subjected to
The primary objective of many control systems is to maintain the output variable at the desired or reference condition when the system is subjected to a disturbance [22]. A typical chemical reactor control scheme. The disturbance is represented by U(s), and the chemical process by G3 and G4. The controller is represented by G{ and the valve by G2. The feedback sensor is H(s) and will be assumed to be equal to l .We will assume that G2, G3, and GA are all of the form
-1.png)
where T3, = T4 = 4 s and #3 = K4 = 0.1. The valve constants are K2 = 20 and T2 = 0.5 s. We want to maintain a steady-state error less than 5% of the desired reference position.
(a) When G(s) = K1. find the necessary gain to satisfy the error-constant requirement. For this condition, determine the expected overshoot to a step change in the reference signal r(f).
(c) Estimate the settling time (with a 2% criterion) of the step response of the system for the controller of parts (a) and (b).
(d) The system is expected to be subjected to a step disturbance U(s) - A/s. For simplicity, assume that the desired reference is r(t) = 0 when the system has settled. Determine the response of the system of part (b) to the disturbance.
Ki G(s)
Step by Step Solution
3.39 Rating (161 Votes )
There are 3 Steps involved in it
a We require e ss 005A and we have or K p 19 But So K p 02K 1 19 or K 1 95 b Given w... View full answer