Question: When a man returns to his well-sealed house on a summer day, he finds that the house is at 35°C. He turns on the air
When a man returns to his well-sealed house on a summer day, he finds that the house is at 35°C. He turns on the air conditioner, which cools the entire house to 20°C in 30 min. If the COP of the air-conditioning system is 2.8, determine the power drawn by the air conditioner. Assume the entire mass within the house is equivalent to 800 kg of air for which cv = 0.72 kJ/kg·°C and cp = 1.0 kJ/kg·°C.
.png)
Win 35 C 20PC A/C
Step by Step Solution
3.52 Rating (172 Votes )
There are 3 Steps involved in it
An air conditioner with a known COP cools a house to desired temperature in 15 m... View full answer
Get step-by-step solutions from verified subject matter experts
Document Format (1 attachment)
837-P-T-S-L (708).docx