Question: A current density of 0.05 A/cm2 is applied to a 150 cm2 cathode. What period of time is required to plate out a 1-mm-thick coating
A current density of 0.05 A/cm2 is applied to a 150 cm2 cathode. What period of time is required to plate out a 1-mm-thick coating of silver onto the cathode?
Step by Step Solution
3.55 Rating (165 Votes )
There are 3 Steps involved in it
The current in the cell is I iA 005 A cm 2 150 cm 2 75 A T... View full answer