A di scharge well that fully penetrates a confined aquifer is pumped at a constant rate of

Question:

A di scharge well that fully penetrates a confined aquifer is pumped at a constant rate of 300 m3/hr. The aquifer transmissivity is 25. 0 m2/ hr, and the storage coefficient is 0.00025. A fully penetrating stream is located 500 m away. Determine the drawdown at a location between the well and the stream (100 mfrom the well and 400 m from the stream) 50 hours after pumping has begun.
Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  book-img-for-question

Fundamentals Of Hydraulic Engineering Systems

ISBN: 978-0136016380

4th Edition

Authors: Robert J. Houghtalen, A. Osman H. Akan, Ned H. C. Hwang

Question Posted: