Steam at 1 atm and 100?C is flowing across a 5-cm-OD tube at a velocity of 6

Question:

Steam at 1 atm and 100?C is flowing across a 5-cm-OD tube at a velocity of 6 m/s. Estimate the Nusselt number, the heat transfer coefficient, and the rate of heat transfer per meter length of pipe if the pipe is at 200?C.GIVENSteam flowing across a tubeSteam pressure = 1 atmSteam bulk temperature (Tb) = 100?CTube outside diameter (D) = 5 cm = 0.05 mSteam velocity (V) = 6 m/sPipe surface temperature (Ts) 200?CASSUMPTIONSSteadystate