Question: You would like to build a synchronizer that can receive asynchronous inputs with an MTBF of 50 years. Your system is running at 1 GHz,
You would like to build a synchronizer that can receive asynchronous inputs with an MTBF of 50 years. Your system is running at 1 GHz, and you use sampling flip-flops with τ = 100 ps, T0 = 110 ps, and tsetup = 70 ps. The synchronizer receives a new asynchronous input on average 0.5 times per second (i.e., once every 2 seconds). What is the required probability of failure to satisfy this MTBF? How many clock cycles would you have to wait before reading the sampled input signal to give that probability of error?
Step by Step Solution
3.21 Rating (162 Votes )
There are 3 Steps involved in it
Pfailuresec 1MTBF 150 years x 315 x 10 7 secyear 634 x 10 10 Pfailuresec waiting f... View full answer