Question: A heat exchanger is to be designed to condense 600 kg/h of steam at atmospheric pressure. A square array of four hundred 1.0-cm-diameter tubes is
A heat exchanger is to be designed to condense 600 kg/h of steam at atmospheric pressure. A square array of four hundred 1.0-cm-diameter tubes is available for the task, and the tube wall temperature is to be maintained at 97oC. Estimate the length of tubes required.
Step by Step Solution
3.42 Rating (168 Votes )
There are 3 Steps involved in it
m 600 kghr 01667 kgs q m h fg 016672255 10 6 q 375 ... View full answer