Question: A stream of hot dry nitrogen flows through a process Unit that contains liquid acetone. A substantial portion of the acetone vaporizes and is carried

A stream of hot dry nitrogen flows through a process Unit that contains liquid acetone. A substantial portion of the acetone vaporizes and is carried off by the nitrogen. The combined gases leave the recovery unit at 205°C and 1.1bar and enter a condenser in which a portion of the acetone is liquefied. The remaining gas leaves the condenser at 10°C and 40bar. The partial pressure of acetone in the feed to the condenser is 0.100bar, and that in the effluent gas from the condenser is 0.379 bar. Assume ideal gas behavior.

(a) Calculate for a basis of 1 m3 of gas fed to the condenser the mass of acetone condensed (kg) and the volume of gas leaving the condenser (m3).

(b) Suppose the volumetric flow rate of the gas leaving the condenser is 20.0m3/h Calculate the rate (kg/h) at which acetone is vaporized in the solvent recovery unit.

Step by Step Solution

3.44 Rating (180 Votes )

There are 3 Steps involved in it

1 Expert Approved Answer
Step: 1 Unlock

Basis 1 m gas fed 205C 11 bars Ac acetone 1 m 205C 11 bar n kmol y kmol ... View full answer

blur-text-image
Question Has Been Solved by an Expert!

Get step-by-step solutions from verified subject matter experts

Step: 2 Unlock
Step: 3 Unlock

Document Format (2 attachments)

PDF file Icon

13-E-C-E-C-P (210).pdf

180 KBs PDF File

Word file Icon

13-E-C-E-C-P (210).docx

120 KBs Word File

Students Have Also Explored These Related Chemical Engineering Questions!