Develop a model of a coal combustor fed with Illinois No. 6 coal, a bituminous coal, at

Question:

Develop a model of a coal combustor fed with Illinois No. 6 coal, a bituminous coal, at 2 atm pressure. The atmospheric air for combustion is available at a temperature of 150°C. The flow of combustion air is 10% more than the stoichiometric requirement. The coal is also available at 150°C. The composition for Illinois No. 6 coal isProximate Analysis (wt%) Moisture Ash Volatile Matter Fixed Carbon 11.12 9.70 34.99 44.19

Ultimate Analysis (wt%) Moisture Carbon Hydrogen Nitrogen Chlorine Sulfur Ash Oxygen 11.12 63.75 4.50 1.25

The combustor is adiabatic. Assume the carbon conversion to be 100%. The high heating value (HHV) of the coal is reported to be 27,113 kJ/kg. Compare the heating value estimated by the process simulator with this reported value. As mentioned before, most of the models for heterogeneous solids are empirical. Modify the parameters of the enthalpy model to match the reported heating value. What is the composition at the outlet of the combustor?

Fantastic news! We've Found the answer you've been seeking!

Step by Step Answer:

Related Book For  answer-question

Analysis Synthesis And Design Of Chemical Processes

ISBN: 9780134177403

5th Edition

Authors: Richard Turton, Joseph Shaeiwitz, Debangsu Bhattacharyya, Wallace Whiting

Question Posted: