Question: The elevation difference between two reservoirs 2,000 m apart is 20 m. Compute the flow rate if (a) A 30-cm commercial steel (CHw = 140)
(a) A 30-cm commercial steel (CHw = 140) pipeline connects the reservoirs and
(b) Two 20-cm commercial pipelines are used instead. Ignore minor losses and verify your results with computer software.
Step by Step Solution
3.44 Rating (160 Votes )
There are 3 Steps involved in it
The energy equation yields h 1 h 2 h f 20 m The HazenWilliams eqn can be writ... View full answer