Question: A network for a process plant is shown in Fig P19.7. (a) Calculate the energy targets for (Delta T_{min }=10{ }^{circ} mathrm{C}) and show a
A network for a process plant is shown in Fig P19.7.
(a) Calculate the energy targets for \(\Delta T_{\min }=10{ }^{\circ} \mathrm{C}\) and show a design that achieves these targets.
(b) Explain why the existing network does not achieve the energy targets.
[
(a) \(Q_{\mathrm{C}_{\text {min }}}=190 \mathrm{~kW} ; Q_{\mathrm{H}_{\text {min }}}=90 \mathrm{~kW}\);
(b) there is transfer across the pinch]

30 Steam 60 kW Heat exchanger 420 kW 110 FIGURE P19.7 Network for problem P19.7. 150 180 70 Process 50 Process 190 160 Steam 500 kW Cooling water 660 kW
Step by Step Solution
3.40 Rating (159 Votes )
There are 3 Steps involved in it
Get step-by-step solutions from verified subject matter experts